Feedback

                            Navigation:Home  ? Industry Projects  ?  Flare

                            The Bio- gas flare

                            The Bio-gas flare fits the “solid waste sanitary landfill technology specification" standard. It creates a beautiful livable environment with clear water and bright sky.
                            Photo Gallery
                            Product Description

                            Technical Feature

                            • Double probe type high-voltage ignition,high reliability
                            • Ultraviolet flame detector and temperature detection double monitoring
                            • Flame arrester
                            • High temperature ceramic fiber insulation layer
                            • The combustion efficiency:99.0%
                            • The natural wind and the forced purge air combination
                            • Stainless steel flare disc and burner
                            • Purge air staging combustion

                            Specifications

                            • Methane concentration: 30%-60%
                            • Combustion temperature:500-1200℃
                            • Residence time:> 0.3S
                            • Turn down range:20%-100%
                            • Inlet gas pressure:> 2Kpa
                            • Sound pressure at full load: less than 85dB
                            • No open flame combustion, low heat radiation.

                            Standard Specifications

                            Model Max.Capacity
                            (Nm3/h)
                            Flange Connection Pressure Size(D*H) Mounting Dimensions Mounting holes Ignition electrodenumber Weight(kg)
                            INTERNAL-300E 300 DN80/PN10 >2KPa ?1000*7000 ?850 8-M30 1 2500
                            INTERNAL-600E 600 DN125/PN10 >2KPa ?1200*7000 ?1050 8-M30 1 2800
                            INTERNAL-1000E 1000 DN150/PN10 >2KPa ?1400*8000 ?1200 8-M30 1 3500
                            INTERNAL-1500E 1500 DN200/PN10 >2KPa ?1600*8000 ?1400 8-M30 1 4800
                            Note: Consult factory for different media can be specific selection



                            Tel:025-84414484 Fax:025-86647595 Address:Wenying Road No.3,Binjiang Development Zone Jiangning District,Nanjing City